The Importance of Fireproofing in High Rise Buildings

One of the key reasons fireproofing in high rise buildings

is essential is because of the time it provides for evacuation and rescue operations. In the event of a fire, occupants on higher floors may have limited means of escape. Fireproofing in high rise buildings that use fireproofing materials and techniques can delay the spread of flames, allowing more time for people to evacuate safely and for emergency responders to reach the affected areas.

As per the 2021 International Building Code, a high-rise building is any structure with an inhabited floor situated more than 75 ft above the lowest level of fire department vehicle access. Because of their elevation, fires in high rise buildings pose a distinctive challenge to fire services for a variety of reasons. Difficulties such as evacuating the building occupants, getting firefighters, medical personnel if necessary, and the required equipment to the fire floor, getting access to the fire for firefighting purposes, ventilating the building, and communicating with the fire command center make it difficult to handle high-rise building fires.

Fireproofing in high rise buildings present unique challenges. Unlike low-rise buildings, high rise structures have limited evacuation options and are more susceptible to rapid fire spread. Fireproofing in high rise buildings plays a crucial role in protecting the lives of the occupants and preventing the loss of property.

The regulations being enforced demand that fire-resistant structures be set up to guarantee both structural safety and compartmentalization of a building, as well as safe passage of egress, protection of any gaps in the fire-resistance construction, the application of interior finishing materials with low flame spread and smoke development, and, most recently, the addition of an extra stairwell with specific elevators for emergency fire services.

According to the fire code, active fire protection devices must be in place, these include automatic sprinkler systems, standpipe systems, fire extinguishers, fire alarms, smoke control systems, smoke and heat vents, fire department connections, fire pumps with protection from service outages, as well as standby and emergency power sources.

Type I and II buildings utilize noncombustible materials for most parts of their structure, though there are some cases where exceptions apply.

Type III buildings are characterized by walls made of fire-resistant material and the interior components can be made of any material allowed by the code. Wood framing and sheathing that has been treated to make it fire-retardant is permissible in exterior walls with a fire rating of 2 hours or less.

Type IV construction involves the use of building elements such as mass timber or noncombustible materials that have a fire-resistance rating.

Type V construction is one in which the materials used for structural components, external walls, and internal walls are allowed as per the code.

fireproofing in high rise buildings starts during the construction phase

The necessity to provide passive fireproofing in high rise buildings became apparent after the tragedy of 9/11. Subsequently, the International Code Council’s Board of Directors formed an adhoc committee – the Terrorism Resistant Building (TRB) committee – to review and suggest revisions to the building code to reinforce the construction of buildings in order to make them more resistant to terrorist attacks. It could be debatable whether the building code should be amended in this regard, nevertheless, the task group did create and propose tougher standards for high-rise edifices.

• An elevated demand for SFRM protection for structures more than 420 feet from a fire department vehicle access, plus more attention to inspection.

• A separation of close-by exit stairways.

• A necessity for impact resistance for key escape shafts for safety.

• An extra exit stairway for the evacuation of building occupants.

• An additional five service elevators for use by fire services during fires.

Aside from the regulations in Section 403 of the International Building Code, there are other criteria in the code that must be fulfilled for materials to be granted fire-resistant ratings, regardless of the height of the building. The section of the code on Fire-Resistance Ratings of Structural Members (704) has specific rules that must be followed when installing SFRM. These include:

1.The implementation of the SFRM (Sprayed Fire-Resistive Material) must be in accordance with the list, taking into consideration but not limited to the least layer thickness and dry density of the material, the way of application, the state of the substrate surface, and the utilization of bonding adhesives, sealants, reinforcing or other components

2. SFRM installation must comply with the manufacturer’s instructions.

3. The substrate to receive the SFRM must be free of dirt, oil, grease, release agents, loose scale, and other conditions that prevent adhesion.

4. When applied over primers, paint or encapsulants other than those specified in the listing, the steel substrate shall meet certain dimensional requirements and minimum bond strength requirements.

5. The temperature minimum during and after the SFRM application.

6. The SFRM that has been dried shall not exhibit cracks, holes, delamination, or any exposure of the substrate.

The Chapter 25 of the IBC contains requirements for the use of gypsum board. According to the ASTMC 1396, “Standard Specification of Gypsum Board”, Type X gypsum board is frequently used in fire resistance-rated construction.

The primary differences in fireproofing in high rise buildings, as discussed in this article, relate to the additional passive and active protection required. The actual fireproofing is not significantly different than fireproofing other buildings, although the required rating periods are longer due to the inherent difficulties of evacuating and fighting high-rise building fires.