14Jun

In the event of elevated temperature, most intumescent paints will expand and produce a char which acts as a thermal insulator for the underlying material. Such coatings may thus be beneficial in providing protection of various structural elements to assist in satisfying the applicable requirements.

When subjected to raised temperatures they expand considerably to provide a relatively massive insulating layer of char over the underlying surface, thereby reducing the rate of heat transmission to it. Hence, if correctly chosen and applied, such paints could maintain structural adequacy for a period of time, and so assist in providing an appropriate degree of fire resistance.

The majority of applications will be to steel structures, although there are a number of products which may be applied to certain timbers, concrete and various foams. In each case, the product will have been tested on the appropriate substrate, so it would be wrong to assume general applicability to other materials.

Action of the paints

In its unactivated state, the paint would be indistinguishable from many other general-finish coatings. Due to the action of heat, various constituents act to produce a greatly swollen mass with good insulating properties.

Generally, there will be a resinous constituent to become plastic on heating, an agent or agents to char and produce carbon, and a foam-producing constituent giving off gas or gases to bring about swelling, thus providing an insulating blanket over the surface being protected. The degree of heating required to initiate this action and the degree of swelling achieved will vary with individual products. It is therefore important to refer to data for the particular product under consideration as to its reaction characteristics and recommended method of application.

Effect of heat on steelwork

Steel will, of course, not combust, but with continued rise in temperature there will be gradual decreases in yield point and elasticity. The load it could safely support in fire will therefore depend upon a number of variables relating to dimensions of section, degree of loading and restraint, severity of fire, and so on. There is no single “critical” temperature.

The function of an intumescent coating would therefore be to retard the rate of temperature increase, allowing a greater load-carrying capacity to be retained by the steelwork for such time as may be demonstrated by a test for any particular arrangement. This may be one aspect of gaining sufficient time for occupants to escape and for the fire brigade to arrive and tackle the fire.

It should be noted that a given number of hours’ fire resistance would apply to a complete construction. For example, various thicknesses of Contego High Solids may be recommended to achieve 2-hour performance, depending on details of the section and other conditions, all of which would be set out in the relevant data.

Importance of correct thickness

It is clearly most important that the correct thickness of dried coating should be achieved. An inadequate thickness will fail to provide the desired degree of protection, and too heavy an application in one or more coats may give rise to inadequate curing and to cracking.

The required thickness depends on:

  • The specified fire-resistance period.
  • The steel member’s geometry and exposure.
  • The applicable tested or listed design.
  • The coating formulation.
  • The approved primer and topcoat system, where required.

A wet-film gauge will generally be used to check the thickness of all or some coats when applying the product. Allowance will need to be made for volume solids and the extent of thinning that may be permitted. In all cases the actual dried film thickness should be checked.

Several coats may be required, each to be applied and dried in accordance with the manufacturer’s recommendations.

Preparation and application of coating

It is essential that all surfaces to be coated are suitable and in good order and that there are no loose or other unwanted materials that may impair bonding. A degree of surface preparation and priming may be specified for steelwork.

Ambient conditions, including temperature and relative humidity, air flow, and the degree of dampness of the base material, may be significant, and appropriate information should be obtained and observed. All aspects of the product installation should be in accordance with relevant information issued by the manufacturer and the requirements of the specification.

Most products may be applied with a range of airless equipment. Some may also be suitable for application by brush or by roller. The size of the pump, pressures, length, and diameter of the hose or hoses and air cap will vary according to the manufacturer’s recommendations for each product. Some can be applied from quite small units, although there will be limits to this.

Allowing exposed steel to remain exposed

There are obvious advantages to being able to leave steelwork unpainted and exposed, and this is a common feature of many types of commercial development.

Where appropriate, the use of a particular system or systems of intumescent coating may therefore be specified instead of some other method of providing the required degree of protection. The thickness is generally sufficiently small to leave the general profile of the section exposed.

There is no inherent reason to expect resistance to corrosion or exposure to the weather. This will be determined by all coats applied to the substrate, such as primer, finish coats, and so on, and suitable products should be specified for external and other exposed locations.

Advantages to the Property Owner

Life safety

Delaying the rate of temperature rise in load-bearing elements may obviously be beneficial in maintaining the integrity of the structure. This would be in addition to other provisions such as sprinklers, detection and alarm, fire-resisting construction, and means of escape.

Minimizing the degree of damage

It is reasonable to assume that an appropriately engineered package would limit the damage sustained and limit loss of use of all or part of a building. This, of course, depends on many factors, such as the scale of the fire, the construction, and the other safeguards provided.

Architectural considerations

Steel sections may be left exposed and still achieve whatever degree of fire resistance may be specified. A wide range of finishes may also be available to give a required effect.

Limitation of risk

Appropriate fire precautions will form one aspect of prudent control of risks to property. Any degree of benefit in terms of loss of property and revenue can, of course, only be estimated. There is no certainty of reduced insurance premiums, which should be investigated by the owner with the insurer.

Aftercare

It will be necessary to ensure adequate attention to all areas coated with intumescent paint if they are to remain effective. The frequency and nature of maintenance will depend upon a variety of considerations, including those recommended by the manufacturer and to which the area may be exposed, as well as general building inspection regimes.

Look for defects

Cracks, flaking, blistering, mechanical damage, wet or corroded areas, and so on. All areas likely to be susceptible, for example, under leakages, as a result of alterations or other work, should be examined carefully.

Repair defects appropriately.

The extent of any defects should be determined and remedied with suitable materials, strictly following procedures recommended by the manufacturer. It will be necessary to reinstate all necessary coats to the required thickness, rather than merely creating an acceptable finish.

Precautions with subsequent coats

Other coats, in particular decorative finishes, should not be applied without satisfying oneself of their suitability. There may well be an adverse effect on fire properties.

Records

It would be prudent to hold records detailing the system applied, any relevant design information and test details, film thickness readings and details of inspections, and any remedial work. This would be useful at subsequent inspection, maintenance, and alteration.

Useful in an overall approach to fire precautions

It can be seen that intumescent paints have much to offer, allowing steel sections to be left exposed, subject to selection and application of an appropriate product or products to an accepted design, checking of thicknesses, and general maintenance.

Much care should therefore be taken that the total scheme of coats to be applied is appropriate to the circumstances, construction, and degree of protection required.

To discuss product options and request application-specific documentation, contact National Fireproofing Supply Co. at (219) 926-1477.

Author

  • Ross Hollister is an experienced private author who studied fire science. His background enabled him to write on issues that concern fireproofing, fire retardants, and fireproofing technologies. Ross' articles explore a topic of interest to anyone concerned with building or product safety and protection from fire damage: what can a particular material do in a case of fire, and what are the limitations of such protection?

Posted in Fireproof Coatings